¹ Colorado School of Mines ² Jožef Stefan Institute and University of Ljubljana
Why the FM? Towards transport-based digital twins
The fission matrix gives 3-D transport at Monte Carlo accuracy in seconds[1]: the engine for real-time, transport-based reactor kinetics, what a reactor digital twin needs.
2009Fission-matrix-based Monte Carlo criticality [2]
2014Continuous-energy fission matrix theory [3]
2015–18RAPID: pin-wise 3-D sources, then whole cores [4,5]
2020–21Control-rod motion; validation on the JSI TRIGA [6,7]
20243-D kinetics: tRAPID, validated on the JSI TRIGA [8,9]
2026, MinesUncertainty quantification of the FM; neural-network thermal feedback [12,13]
NextReal-time 3-D transport-based kinetics: reactor digital twins
Selected milestones. Dashed: a goal, not yet demonstrated.
The fission matrix in one picture
Illustrative 19-cell core and matrix (not a calculation). Our model has 645 cells.
How it works
Tally each aij once with Monte Carlo
Solve S = AS/k by power iteration, in seconds
Core changes: update aij, re-solve
Only as accurate as its aij
Two routes to the same coefficients
One run: all columns, plus the reference
Source inside each cell: converged, self-consistent
Needs a converged, verified source
One run per column: 645 in our model
Source inside each cell: assumed (uniform, Watt)
No source convergence needed
Both routes are in use, but a formal comparison was needed and never done. This work: how accurate is each route, what drives the difference, and which should you use?
Illustrative animation. The within-cell radial trend of the criticality source follows our fission bank (0.84 to 1.24 of uniform).
1 pcmcriticality FM vs. OpenMC track length: 1.00819 ± 5 pcm vs. 1.00820 ± 6 pcm
< 20inactive cycles to converge the source; 50 used, 645 active, 106 per batch
OpenMC [14] model of the core 133 benchmark [15]: radial (left) and axial (right) viewsReference 3-D fission source S (criticality FM, 106-50-645), 645 cells, unit sum [16]Relative statistical uncertainty σS/S of the reference source, scale 0 to 0.25% [16]
The converged source inside each cell
Fission bank of a 107-particle criticality run (107 sites) versus uniform, Watt sampling [16]
Component of the bankWorth in kFM (pcm)
RadialCrowds the outer radius: 0.84 to 1.24 of uniform−27
AzimuthalCore-facing side in 18 of 24 rods; far side in 16 of 18 next to water+85
AxialLeans toward the core midplane: 0.97 to 1.05+99
EnergyENDF/B-VIII.1 prompt and delayed, not Watt+324
Radial: the largest shape departure (Kolmogorov-Smirnov distance 86× critical) is worth only −27 pcm, about 2σ with bank noise
Energy drives the eigenvalue bias
ΔkFM = kFM − kFMcrit, replacing the uniform, Watt source with the bank one component at a time (a diagnostic); tally error bars, bank resampling not included.
From −504 to −24 pcm
Energy: +324 of the +480 pcm
Radial −27, azimuthal +85
Axial +99: full bank at −24 ± 15 pcm
ENDF energies: same gain, no bank
Geometry drives the source shape
Uniform, Watt
Left: (S − Sref)/Sref, common ±2.5% scale. Right: RMSE of the 645 source fractions (mean 1.55 × 10−3, so 10 × 10−6 ≈ 0.6%) and |Δk|. Bank radius, bank x-y, and full bank also take their energies from the bank; the global run is uniform, Watt in one run.
Axial source: effect of the assumptions
Criticality referenceUniform, WattUniform, bank energyBank x-yFull bankBank geometry, WattGlobal run
Axial source summed over the 43 positions (left) and relative difference from the criticality reference (right), ±1σ [16]
Axial shape
All cases within 1.2% at every level
Uniform-z cases: −0.3 to −0.5% at the peak, +0.5 to +1.2% at the ends
Bank geometry, Watt: about 3× smaller; full bank: within about 0.1%
Accuracy versus computing cost
6.45 × 108 histories per run; 64 cores, except uniform, ENDF energy (32 cores, so its time is not comparable). Bank cases are diagnostics, not shown.
What each answer costs
Criticality FM: 1 run, 254 min, the reference
Global run: 645 runs to 1, 84× less storage
Same bias as 645 runs: +19 pcm
Pros and cons of the two routes
Criticality route
Fixed-source route
Setup
1 calculation, all columns
645 runsor 1 global run
Reference k and source
From the same run
Needs a separate run
Source convergence
Required; can be poor
Avoided entirely
Low-source cells
Fewer histories; convergence issues propagate
Histories set per column
Source inside a cell
Converged, self-consistent
Assumed: biases the matrix
kFM bias*
≈1 pcm vs. track length
−504 pcm, Watt−183 pcm, ENDF energies
3-D source, max |δ|
Matches the OpenMC tally
1.8 to 2.3%, radially flat
Easing the bias
Not needed
Richer sources, at more complexity
strengthtrade-offweakness
*Fixed-source biases versus the criticality FM; the criticality FM versus the OpenMC track-length k. Convergence problems are often hard to detect [17].
Takeaways and recommendations
Both routes reproduce the 3-D source within 2.5%. Only the criticality route reproduces k: 1 pcm, against −504 pcm.
The fixed-source bias is the assumed in-cell source. The bank diagnostic shows energy sets k and geometry sets the shape.
ENDF energies remove 2/3 of the bias with no extra calculation (−183 pcm). Richer sources cut more, at more complexity.
One global run replaces 645 (+19 pcm, 84× less storage).
Accurate coefficients are what make real-time 3-D transport, and reactor kinetics digital twins, possible.
References (1 of 2)
A. Haghighat, K. Royston, and W. Walters, “MRT methodologies for real-time simulation of nonproliferation and safeguards problems,” Ann. Nucl. Energy, vol. 87, pp. 61–67, 2016. doi:10.1016/j.anucene.2015.06.004
J. Dufek and W. Gudowski, “Fission matrix based Monte Carlo criticality calculations,” Ann. Nucl. Energy, vol. 36, pp. 1270–1275, 2009. doi:10.1016/j.anucene.2009.05.003
S. Carney, F. Brown, B. Kiedrowski, and W. Martin, “Theory and applications of the fission matrix method for continuous-energy Monte Carlo,” Ann. Nucl. Energy, vol. 73, pp. 423–431, 2014. doi:10.1016/j.anucene.2014.07.020
W. Walters, N. Roskoff, and A. Haghighat, “A fission matrix approach to calculate pin-wise 3-D fission density distribution,” M&C+SNA+MC 2015, Nashville, TN, USA, pp. 1351–1361, 2015.
W. J. Walters, N. J. Roskoff, and A. Haghighat, “The RAPID fission matrix approach to reactor core criticality calculations,” Nucl. Sci. Eng., vol. 192, no. 1, pp. 21–39, 2018. doi:10.1080/00295639.2018.1497395
D. He and W. J. Walters, “A correction method for RAPID fission matrix calculations with control rod movement,” Prog. Nucl. Energy, vol. 121, 103226, 2020. doi:10.1016/j.pnucene.2019.103226
V. Mascolino, A. Haghighat, and L. Snoj, “Verification and validation of RAPID formulations and algorithms based on dosimetry measurements at the JSI TRIGA Mark-II reactor,” Nucl. Sci. Eng., vol. 195, no. 9, pp. 937–953, 2021. doi:10.1080/00295639.2021.1890321
V. Mascolino and A. Haghighat, “A novel hybrid deterministic and Monte Carlo neutron transport formulation and algorithm (tRAPID) for accurate and fast 3-D reactor kinetics,” Nucl. Sci. Eng., vol. 198, no. 3, pp. 592–627, 2024. doi:10.1080/00295639.2023.2197844
V. Mascolino, A. Pungerčič, L. Snoj, and A. Haghighat, “Experimental validation of the 3-D neutron kinetics algorithm of RAPID using the JSI TRIGA Mark-II reactor,” Prog. Nucl. Energy, vol. 176, 105391, 2024. doi:10.1016/j.pnucene.2024.105391
C. Vita, N. Abrate, S. Dulla, W. Walters, V. Mascolino, N. E. Stauff, and F. Franceschini, “FIM4NTRA: A code for neutronics analyses based on the fission matrix method,” Trans. Am. Nucl. Soc., vol. 133, no. 1, pp. 771–774, 2025. doi:10.13182/T133-49227
C. Vita, N. Abrate, S. Dulla, V. Mascolino, W. Walters, N. E. Stauff, and F. Franceschini, “The fission matrix method for criticality search in heat-pipe micro reactors,” preprint, SSRN, 2026. doi:10.2139/ssrn.6843583
V. Mascolino, “Uncertainty quantification for the fission matrix method: a rigorous mathematical framework and computationally efficient alternatives,” preprint, arXiv:2609.33161, 2026.
D. Paine and V. Mascolino, “Neural network-enabled thermal feedback modeling in the fission matrix method,” Trans. Am. Nucl. Soc., vol. 134, pp. 652–655, 2026. doi:10.13182/T134-11738
P. K. Romano, N. E. Horelik, B. R. Herman, A. G. Nelson, B. Forget, and K. Smith, “OpenMC: A state-of-the-art Monte Carlo code for research and development,” Ann. Nucl. Energy, vol. 82, pp. 90–97, 2015. doi:10.1016/j.anucene.2014.07.048
R. Jeraj and M. Ravnik, “TRIGA Mark II reactor: U(20)-zirconium hydride fuel rods in water with graphite reflector,” International Handbook of Evaluated Criticality Safety Benchmark Experiments, NEA/NSC/DOC(95)03/III, OECD Nuclear Energy Agency, 1999.
S. Balouza, M. Krašovic, A. Pungerčič, and V. Mascolino, “Evaluation of fission matrix generation techniques in OpenMC: convergence, uncertainty, and application to the JSI TRIGA Mark-II reactor,” journal article in preparation, 2026.
V. Mascolino, A. Haghighat, and N. J. Roskoff, “Evaluation of RAPID for a UNF cask benchmark problem,” EPJ Web of Conferences, vol. 153, 05025, 2017. doi:10.1051/epjconf/201715305025
References (2 of 2)
A. Haghighat, K. Royston, and W. Walters, “MRT methodologies for real-time simulation of nonproliferation and safeguards problems,” Ann. Nucl. Energy, vol. 87, pp. 61–67, 2016. doi:10.1016/j.anucene.2015.06.004
J. Dufek and W. Gudowski, “Fission matrix based Monte Carlo criticality calculations,” Ann. Nucl. Energy, vol. 36, pp. 1270–1275, 2009. doi:10.1016/j.anucene.2009.05.003
S. Carney, F. Brown, B. Kiedrowski, and W. Martin, “Theory and applications of the fission matrix method for continuous-energy Monte Carlo,” Ann. Nucl. Energy, vol. 73, pp. 423–431, 2014. doi:10.1016/j.anucene.2014.07.020
W. Walters, N. Roskoff, and A. Haghighat, “A fission matrix approach to calculate pin-wise 3-D fission density distribution,” M&C+SNA+MC 2015, Nashville, TN, USA, pp. 1351–1361, 2015.
W. J. Walters, N. J. Roskoff, and A. Haghighat, “The RAPID fission matrix approach to reactor core criticality calculations,” Nucl. Sci. Eng., vol. 192, no. 1, pp. 21–39, 2018. doi:10.1080/00295639.2018.1497395
D. He and W. J. Walters, “A correction method for RAPID fission matrix calculations with control rod movement,” Prog. Nucl. Energy, vol. 121, 103226, 2020. doi:10.1016/j.pnucene.2019.103226
V. Mascolino, A. Haghighat, and L. Snoj, “Verification and validation of RAPID formulations and algorithms based on dosimetry measurements at the JSI TRIGA Mark-II reactor,” Nucl. Sci. Eng., vol. 195, no. 9, pp. 937–953, 2021. doi:10.1080/00295639.2021.1890321
V. Mascolino and A. Haghighat, “A novel hybrid deterministic and Monte Carlo neutron transport formulation and algorithm (tRAPID) for accurate and fast 3-D reactor kinetics,” Nucl. Sci. Eng., vol. 198, no. 3, pp. 592–627, 2024. doi:10.1080/00295639.2023.2197844
V. Mascolino, A. Pungerčič, L. Snoj, and A. Haghighat, “Experimental validation of the 3-D neutron kinetics algorithm of RAPID using the JSI TRIGA Mark-II reactor,” Prog. Nucl. Energy, vol. 176, 105391, 2024. doi:10.1016/j.pnucene.2024.105391
C. Vita, N. Abrate, S. Dulla, W. Walters, V. Mascolino, N. E. Stauff, and F. Franceschini, “FIM4NTRA: A code for neutronics analyses based on the fission matrix method,” Trans. Am. Nucl. Soc., vol. 133, no. 1, pp. 771–774, 2025. doi:10.13182/T133-49227
C. Vita, N. Abrate, S. Dulla, V. Mascolino, W. Walters, N. E. Stauff, and F. Franceschini, “The fission matrix method for criticality search in heat-pipe micro reactors,” preprint, SSRN, 2026. doi:10.2139/ssrn.6843583
V. Mascolino, “Uncertainty quantification for the fission matrix method: a rigorous mathematical framework and computationally efficient alternatives,” preprint, arXiv:2609.33161, 2026.
D. Paine and V. Mascolino, “Neural network-enabled thermal feedback modeling in the fission matrix method,” Trans. Am. Nucl. Soc., vol. 134, pp. 652–655, 2026. doi:10.13182/T134-11738
P. K. Romano, N. E. Horelik, B. R. Herman, A. G. Nelson, B. Forget, and K. Smith, “OpenMC: A state-of-the-art Monte Carlo code for research and development,” Ann. Nucl. Energy, vol. 82, pp. 90–97, 2015. doi:10.1016/j.anucene.2014.07.048
R. Jeraj and M. Ravnik, “TRIGA Mark II reactor: U(20)-zirconium hydride fuel rods in water with graphite reflector,” International Handbook of Evaluated Criticality Safety Benchmark Experiments, NEA/NSC/DOC(95)03/III, OECD Nuclear Energy Agency, 1999.
S. Balouza, M. Krašovic, A. Pungerčič, and V. Mascolino, “Evaluation of fission matrix generation techniques in OpenMC: convergence, uncertainty, and application to the JSI TRIGA Mark-II reactor,” journal article in preparation, 2026.
V. Mascolino, A. Haghighat, and N. J. Roskoff, “Evaluation of RAPID for a UNF cask benchmark problem,” EPJ Web of Conferences, vol. 153, 05025, 2017. doi:10.1051/epjconf/201715305025
Thank you! Questions?
Valerio Mascolino valerio.mascolino@mines.edu
M-PRISM Research Group Nuclear Science and Engineering Program, Mechanical Engineering Department, and Colorado School of Mines
vmascolino.com
vmascolino.com
Backup
Convergence, precision, all cases, and source maps
Backup: criticality FM convergence
Shannon entropy and kgeneration for 20 (a) and 100 (b) inactive cycles [16]
Inactive-cycle study
Source settles in 10 to 15 batches
kFM flat from 20 to 100 inactive
kFM − kTL ≈ −1 pcm in every run
Backup: FM precision follows 1/√N
σ of kFM and kTL versus particles per batch, 50 inactive and 645 active cycles [16]
Statistically well behaved
Two decades of Np, on the 1/√N line
σ(kFM) below σ(kTL) at every Np
Backup: all fixed-source cases
Case
Spatial source
Energy
Δkcrit (pcm)
RMSE (10−6)
Axial RMSE (10−5)
Time (min)
Storage
Uniform, Watt
Uniform
Watt
−504
12.3
27.0
378
6.6 GB
Uniform, bank energy
Uniform
Bank
−180
10.7
22.3
367
7.4 GB
Uniform, ENDF energy
Uniform
ENDF/B-VIII.1
−183
10.7
21.5
521*
7.4 GB
Bank radius
Bank r, uniform φ, z
Bank
−208
9.84
20.5
493*
7.4 GB
Bank x-y
Bank x-y, uniform z
Bank
−123
6.54
23.3
397
7.4 GB
Full bank
Full bank
Bank
−24
3.08
3.61
397
7.4 GB
Bank geometry, Watt
Full bank
Watt
−358
4.13
8.45
390
7.4 GB
Global run
Uniform
Watt
−485
12.4
27.1
236
81 MB
Δkcrit versus kFMcrit = 1.00819 ± 5 pcm (106-50-645, 254 min, 162 MB). 6.45 × 108 histories per case, 64 cores. *32 cores, not comparable.
Backup: source differences, all cases
Left: uniform, Watt and uniform, bank energy (top); uniform, ENDF energy and bank radius (bottom). Right: bank x-y and full bank (top); bank geometry, Watt and global run (bottom). ±2.5%.
Patterns
Uniform cases: inner rings low, outer ends high
Bank x-y: axial pattern only
Full bank: within ±0.68%
Backup: full bank against the reference
Sfull bank − Sref (left) and the relative uncertainty of the reference, 0 to 0.25% (right)
No systematic pattern
RMSE 3.08 × 10−6
Largest deviations in the low-source E ring
Backup: global versus column by column
Uniform, Watt fission source from 645 runs (left) and from 1 global run (right), common color scale
Same answer, one run
Pairwise RMSE 3.50 × 10−6
k differs by +19 pcm
Columns normalized by cell volume
→ or clicker: next · ←: back · P: presenter view · R: reveal answer · T: 60 s timer · B: black screen · S: pause animation · F: full screen · G: go to slide