D, Σa, νΣf are effective, flux-weighted one-group data, ideally functions of space only
Rod motion and burnup change them inside δV = Vfuel ∪ VCR
Keep the reference operator ; move the deviations into a source term Q
One-group diffusion
Reference state + deviations (zero outside δV)
Operator split
Kirchhoff–Helmholtz reconstruction
G: response of at x to a point source at x′
KH integral: flux anywhere from φ and ∇nφ on the boundary ∂V plus the interior source Q
No closed-form G for a heterogeneous core, so an ANN approximates G with the KH integral embedded in training
Train: effective data in V, plus φ and ∇nφ at a few points on ∂V; no interior reference fluxes
Test: learned G + boundary measurements → φ everywhere, in real time
Green’s function
Kirchhoff–Helmholtz integral
G of the reference operator (no fission) for one x-y slice of the CRC 1 data on slide 8 (digitized); 2-D, zero flux at the mesh edge. Not GRACE’s learned G.
Two assumptions to test
Making one-group diffusion GRACE’s governing model implies:
1Weak dependency of effective data on reactor parameters
Outside of materially perturbed regions, D, Σa, and νΣf do not change with operating state
Test 1: tally one-group cross sections for seven control-rod configurations
2Symmetry of G holds to within very good precision
is self-adjoint, so G(x, x′) = G(x′, x): swapping source and detector gives the same response
Test 2: swap every source–detector pair in continuous-energy transport
If both hold, one reference Green’s function, or a small library, can cover the operating envelope
JSI TRIGA Mark-II benchmark
250 kW pool-type research reactor in Ljubljana, Slovenia
Six rings of U-ZrH fuel; four B4C rods: REGU, SHIM, SAFE (fuel-followed) and TRAN (air-followed)
Graphite reflector with a 40-position irradiation carousel: future detector sites for validating GRACE
Well characterized benchmark, modeled in OpenMC at high fidelity; the compact core is a useful SMR testbed
JSI TRIGA reactor containment [6]
OpenMC model, x-y view
OpenMC model, x-z view
Effective one-group data on a mesh
OpenMC tallies Σtr, Σa, Σs, νΣf on a rectilinear mesh spanning core and reflector
CRC 1 is not a realistic operating state, but it is the natural reference: every δΣ = 0
Click a row. Schematic: absorber travel drawn in proportion to steps from withdrawn to 900.
Absorption cross-section changes
Rod regions saturate red: B4C
Σa falls around inserted rods: the local spectrum hardens, and the effect fades with distance
Graphite next to ring D rods: slight increase; elsewhere a slight decrease
No materials change outside rod regions, so every change is spectral
within ±1 %in the reflector
within ±10 %in the core
Percent change in Σa relative to CRC 1 (x-y slice; 4 × 4 cm voxels, 124 cm across). Values digitized from the figure’s colors (resolution 0.08 %); dashed line: core.
Scattering and ν-fission changes
CRC 1 → CRC 2 (all rods inserted)
Σs: smaller change than Σa in the core; barely visible in the reflector
Carbon’s microscopic scattering cross section is nearly flat from 1 eV to 1 MeV
νΣf: changes only in the core, where fission occurs
Rod insertion hardens the core spectrum; reflector data barely move
Percent change from CRC 1 to CRC 2 (x-y slice; 4 × 4 cm voxels, 124 cm across). Values digitized from the figure’s colors (resolution 0.08 %); dashed line: core.
Core-averaged changes
Magnitude of the average change in the core vs. CRC 1 (the maps show Σa, Σs, and νΣf decreasing). Average MC 1σ: 0.09–0.15 % for every CRC and reaction. Control-rod regions and reflector excluded.
Resolved above MC statistics, but small
CRC 1 is an extreme reference, so these are upper bounds; a mid-range reference (e.g., CRC 4) would shrink them
One reference GF, or a small library, looks feasible
5.9 %
largest core-averaged change (νΣf, all rods in), against ~0.1 % MC uncertainty
Green’s-function reciprocity
One-group diffusion: is self-adjoint, so swapping source and detector gives the same response
Continuous-energy transport is not self-adjoint: reciprocity holds only if energies (and directions) are swapped too
A fission-spectrum source and a detector integrated over energy weight the two directions differently
Measured asymmetry = how far full transport departs from monoenergetic diffusion
Equal by construction in one-group diffusion; in transport, equal only as far as the reactor behaves monoenergetically
Full-core fixed-source sweep
OpenMC JSI TRIGA model, rods all withdrawn (as CRC 1) and all inserted (as CRC 2)
Each fuel rod → 15 axial segments (2.54 cm): 885 sites (rods out), 840 (rods in)
3 × 106 histories per source; fluxes are cell averages per source particle
Tally generation workflow adopted from the Fission Matrix Methodology, a research focus of M-PRISM
Flux asymmetry factor
Response fraction (share of flux in r supplied by r′)
Global L1 norm (gap as a share of all tallied flux)
Reciprocity results
|FAF| vs. response fraction, all rods withdrawn
|FAF| vs. response fraction, all rods inserted
L1 = 0.87 %
L1 = 1.41 %
Large |FAF| only for weakly coupled pairs (x → 0); pairs that matter stay within a few %
Conclusions
Findings
One-group cross sections move only modestly with rod position: ≤ 5.9 % core-averaged (νΣf), within ±10 % locally in the core and ±1 % in the reflector
Rod insertion lowers Σa by hardening the core spectrum
The transport Green’s function is reciprocal to ~1 % of total flux (L1 = 0.87 % rods out, 1.41 % rods in)
Next steps
Ongoing research seeks to evaluate the magnitude of the total change the diffusion operator experiences with varying control rod positioning
Learn G at a reference CRC; reconstruct flux across CRCs with reference data
Experimental validation using the JSI irradiation carousel
Both tests support one-group diffusion as GRACE’s governing model: one reference Green’s function, or a small library, looks feasible across rod positions
Thank you
Questions?
Jake LaFore
Undergraduate Researcher · Engineering Physics Major
jake_lafore@mines.edu
M-PRISM Research Group Nuclear Science and Engineering Program Mechanical Engineering Department Colorado School of Mines
Nu-fission cross sections vary on the order of a few percent
Little to no change in other cross sections
Percent change from fresh fuel to 1 year of continuous 250 kW operation (x-y slice; 4 × 4 cm voxels, 124 cm across). Values digitized from the figure’s colors (resolution 0.04 %); dashed line: core.
Changes scale with rod insertion
Derived from the tables on slides 9 and 12; not part of the ANS summary. Mean insertion: the four rods weighted equally (TRAN is air-followed), as a fraction of travel from withdrawn to 900 steps. Lines: fits through zero.
What to see
Core-averaged changes grow almost linearly with how far the rods are in.
References
Reactor vessel being installed at Hinkley Point C, England. nucnet.com, 2026.
Valar Atomics Ward 250 being loaded on a C-17. aerospaceglobalnews.com, 2026.
R. Ponciroli, H. Wang, V. Theos, J. Lau, S. Chatzidakis, and R. B. Vilim, “Ex-Core Neutron-Flux Reconstruction using Machine-Learned Green’s Kernels and Flux-Gradient Measurements,” Nuclear Science and Engineering, 2026. doi:10.1080/00295639.2026.2690565
R. Ponciroli, H. Wang, V. Theos, J. Lau, S. Chatzidakis, and R. B. Vilim, “Who Needs Big Data? Small-Data Flux Reconstruction via Green’s Functions and Ex-Core Detectors,” Proc. PHYSOR 2026.
H. Wang, R. Ponciroli, J. Lau, V. Theos, S. Chatzidakis, and R. B. Vilim, “Measuring Neutron Flux Gradient: Design, Prototyping, and Deployment of a Novel Sensor at the PUR-1 Research Reactor,” Proc. PHYSOR 2026.
JSI TRIGA reactor containment. EURO-LABS, 2026.
→ or clicker: next · ←: back · P: presenter view · R: reveal answer · T: 60 s timer · B: black screen · S: pause animation · F: full screen · G: go to slide