Computational analyses to support the GRACE flux reconstruction methodology for next-generation reactors

Jake LaFore¹, Haoyu Wang², Anže Pungerčič³, Roberto Ponciroli², Valerio Mascolino¹
¹ Colorado School of Mines    ² Argonne National Laboratory    ³ Jožef Stefan Institute
Jožef Stefan Institute
Argonne National Laboratory
M-PRISM

Monitoring flux in compact reactors

  • In-core detector networks map the flux in large LWRs
  • SMRs and microreactors leave little or no room for in-core instruments (space, cost, harsh thermal and radiation environment)
  • The flux distribution is still needed for monitoring, control, and safe operation
  • Ex-core detectors are accessible, but inferring the in-core flux from them is an ill-posed inverse problem
Reactor vessel being installed at Hinkley Point C
Large LWR: Hinkley Point C vessel [1]
vs.
Valar Atomics Ward 250 being loaded on a C-17
Microreactor: Valar Atomics Ward 250 [2]

The GRACE method

Green’s-kernel Reconstruction from Accessible Ex-core Measurements [3,4,5]
  • Physics-directed ML: an ANN learns the operator’s Green’s function (GF)
  • Kirchhoff–Helmholtz integral rebuilds φ throughout the core from boundary flux and gradient data
  • No reference fluxes in training: the ANN uses only one-group nuclear data
    • A much more demanding coupled nonlinear solve, but it reflects real experimental conditions
  • Small-data: embedded physics reduces the data needed and aims to generalize to unseen states
One-group nuclear dataD, Σa, νΣf
ANN learns G(x, x′)
Kirchhoff–Helmholtz integral
Boundary measurementsφ, ∇nφ on ∂V
3-D flux φ(x) in real time

GRACE’s governing model

  • Governing model: one-group diffusion (steady state)
  • D, Σa, νΣf are effective, flux-weighted one-group data, ideally functions of space only
  • Rod motion and burnup change them inside δV = Vfuel ∪ VCR
  • Keep the reference operator \mathcal{L}; move the deviations into a source term Q
One-group diffusion
-\nabla\cdot\left[D(\mathbf{x})\,\nabla\phi(\mathbf{x})\right]+\Sigma_a(\mathbf{x})\,\phi(\mathbf{x})=\nu\Sigma_f(\mathbf{x})\,\phi(\mathbf{x}) D=\frac{1}{3\Sigma_{tr}}=\frac{1}{3\left[\Sigma_a+\Sigma_s(1-\bar{\mu})\right]}
Reference state + deviations (zero outside δV)
D=D_0+\delta D,\quad \Sigma_a=\Sigma_{a,0}+\delta\Sigma_a,\quad \nu\Sigma_f=(\nu\Sigma_f)_0+\delta(\nu\Sigma_f)
Operator split
\mathcal{L}\phi=-\nabla\cdot(D_0\nabla\phi)+\Sigma_{a,0}\,\phi=Q Q(\mathbf{x})=\begin{cases}(\nu\Sigma_f-\delta\Sigma_a)\,\phi+\nabla\cdot(\delta D\,\nabla\phi), & \mathbf{x}\in\delta V\\ 0, & \mathbf{x}\notin\delta V\end{cases}

Kirchhoff–Helmholtz reconstruction

  • G: response of \mathcal{L} at x to a point source at x′
  • KH integral: flux anywhere from φ and ∇nφ on the boundary ∂V plus the interior source Q
  • No closed-form G for a heterogeneous core, so an ANN approximates G with the KH integral embedded in training
  • Train: effective data in V, plus φ and ∇nφ at a few points on ∂V; no interior reference fluxes
  • Test: learned G + boundary measurements → φ everywhere, in real time
Green’s function
\mathcal{L}\,G(\mathbf{x},\mathbf{x}')=\delta(\mathbf{x}-\mathbf{x}')
Kirchhoff–Helmholtz integral
\phi(\mathbf{x})=\oint_{\partial V}\left[G\,D\,\nabla_n\phi-\phi\,D\,\nabla_n G\right]dS'+\int_V G\,Q\,dV'
G of the reference operator \mathcal{L} (no fission) for one x-y slice of the CRC 1 data on slide 8 (digitized); 2-D, zero flux at the mesh edge. Not GRACE’s learned G.

Two assumptions to test

Making one-group diffusion GRACE’s governing model implies:
1Weak dependency of effective data on reactor parameters

Outside of materially perturbed regions, D, Σa, and νΣf do not change with operating state

Test 1: tally one-group cross sections for seven control-rod configurations

2Symmetry of G holds to within very good precision

\mathcal{L} is self-adjoint, so G(x, x′) = G(x′, x): swapping source and detector gives the same response

Test 2: swap every source–detector pair in continuous-energy transport

If both hold, one reference Green’s function, or a small library, can cover the operating envelope

JSI TRIGA Mark-II benchmark

  • 250 kW pool-type research reactor in Ljubljana, Slovenia
  • Six rings of U-ZrH fuel; four B4C rods: REGU, SHIM, SAFE (fuel-followed) and TRAN (air-followed)
  • Graphite reflector with a 40-position irradiation carousel: future detector sites for validating GRACE
  • Well characterized benchmark, modeled in OpenMC at high fidelity; the compact core is a useful SMR testbed
JSI TRIGA reactor containment
JSI TRIGA reactor containment [6]
OpenMC model of the JSI TRIGA, x-y view
OpenMC model, x-y view
OpenMC model of the JSI TRIGA, x-z view
OpenMC model, x-z view

Effective one-group data on a mesh

  • OpenMC tallies Σtr, Σa, Σs, νΣf on a rectilinear mesh spanning core and reflector
  • 124 × 124 × 64 cm: 31 × 31 × 8 voxels of 4 × 4 × 8 cm (7,688 voxels)
  • Voxels mix fuel, water, cladding, and structure → homogenized, effective data
  • 5 × 106 particles/batch; 50 inactive + 250 active batches; seven rod configurations
One-group cross sections for CRC 1, x-y slice, four panels
One-group cross sections for CRC 1 (x-y). Clockwise from top left: Σa, Σs, νΣf, Σtr.

Control rod configurations (CRCs)

CRCRod position (steps)Configuration
TRANREGUSHIMSAFE
10181200200All rods fully withdrawn (reference)
2900900900900All rods fully inserted
3450541550550All rods inserted at 50 %
4900800560200Critical configuration
50191900200One rod (SHIM) fully inserted, rest withdrawn
60900900200Two rods (REGU, SHIM) fully inserted, two withdrawn
7600600600600All rods inserted to the same level
  • Fully inserted = 900 steps; fully withdrawn = 0 (TRAN), 181 (REGU), 200 (SHIM, SAFE)
  • CRC 1 is not a realistic operating state, but it is the natural reference: every δΣ = 0
Click a row. Schematic: absorber travel drawn in proportion to steps from withdrawn to 900.

Absorption cross-section changes

  • Rod regions saturate red: B4C
  • Σa falls around inserted rods: the local spectrum hardens, and the effect fades with distance
  • Graphite next to ring D rods: slight increase; elsewhere a slight decrease
  • No materials change outside rod regions, so every change is spectral
within ±1 %in the reflector
within ±10 %in the core
Percent change in Σa relative to CRC 1 (x-y slice; 4 × 4 cm voxels, 124 cm across). Values digitized from the figure’s colors (resolution 0.08 %); dashed line: core.

Scattering and ν-fission changes

  • CRC 1 → CRC 2 (all rods inserted)
  • Σs: smaller change than Σa in the core; barely visible in the reflector
    • Carbon’s microscopic scattering cross section is nearly flat from 1 eV to 1 MeV
  • νΣf: changes only in the core, where fission occurs
Percent change from CRC 1 to CRC 2 (x-y slice; 4 × 4 cm voxels, 124 cm across). Values digitized from the figure’s colors (resolution 0.08 %); dashed line: core.

Core-averaged changes

Magnitude of the average change in the core vs. CRC 1 (the maps show Σa, Σs, and νΣf decreasing). Average MC 1σ: 0.09–0.15 % for every CRC and reaction. Control-rod regions and reflector excluded.
  • Resolved above MC statistics, but small
  • CRC 1 is an extreme reference, so these are upper bounds; a mid-range reference (e.g., CRC 4) would shrink them
  • One reference GF, or a small library, looks feasible
5.9 %

largest core-averaged change (νΣf, all rods in), against ~0.1 % MC uncertainty

Green’s-function reciprocity

  • One-group diffusion: \mathcal{L} is self-adjoint, so swapping source and detector gives the same response
  • Continuous-energy transport is not self-adjoint: reciprocity holds only if energies (and directions) are swapped too
  • A fission-spectrum source and a detector integrated over energy weight the two directions differently
  • Measured asymmetry = how far full transport departs from monoenergetic diffusion
\mathcal{L}=\mathcal{L}^{\dagger}\;\;\Rightarrow\;\;G(\mathbf{x},\mathbf{x}')=G(\mathbf{x}',\mathbf{x})\bar{\phi}(A\to B)\overset{?}{=}\bar{\phi}(B\to A)
Equal by construction in one-group diffusion; in transport, equal only as far as the reactor behaves monoenergetically

Full-core fixed-source sweep

  • OpenMC JSI TRIGA model, rods all withdrawn (as CRC 1) and all inserted (as CRC 2)
  • Each fuel rod → 15 axial segments (2.54 cm): 885 sites (rods out), 840 (rods in)
  • 3 × 106 histories per source; fluxes are cell averages per source particle
  • Tally generation workflow adopted from the Fission Matrix Methodology, a research focus of M-PRISM
Flux asymmetry factor
\mathrm{FAF}(r\to r')=\left[\frac{\bar{\phi}(r'\to r)}{\bar{\phi}(r\to r')}-1\right]\times 100\,\%
Response fraction (share of flux in r supplied by r′)
x(r\to r')=\frac{\bar{\phi}(r'\to r)}{\sum_k \bar{\phi}(k\to r)}
Global L1 norm (gap as a share of all tallied flux)
L_1=\frac{\sum_{r,r'}\left|\bar{\phi}(r'\to r)-\bar{\phi}(r\to r')\right|}{2\sum_{r,r'}\bar{\phi}(r\to r')}\times 100\,\%

Reciprocity results

Absolute FAF versus response fraction, all rods withdrawn
Absolute FAF versus response fraction, all rods inserted
|FAF| vs. response fraction, all rods withdrawn
|FAF| vs. response fraction, all rods inserted
L1 = 0.87 %
L1 = 1.41 %
Large |FAF| only for weakly coupled pairs (x → 0); pairs that matter stay within a few %

Conclusions

Findings

  • One-group cross sections move only modestly with rod position: ≤ 5.9 % core-averaged (νΣf), within ±10 % locally in the core and ±1 % in the reflector
  • Rod insertion lowers Σa by hardening the core spectrum
  • The transport Green’s function is reciprocal to ~1 % of total flux (L1 = 0.87 % rods out, 1.41 % rods in)

Next steps

  • Ongoing research seeks to evaluate the magnitude of the total change the diffusion operator experiences with varying control rod positioning
  • Learn G at a reference CRC; reconstruct flux across CRCs with reference data
  • Experimental validation using the JSI irradiation carousel

Thank you

Questions?
Jake LaFore
Undergraduate Researcher · Engineering Physics Major
jake_lafore@mines.edu
M-PRISM Research Group
Nuclear Science and Engineering Program
Mechanical Engineering Department
Colorado School of Mines
Advisor: Valerio Mascolino · valerio.mascolino@mines.edu · vmascolino.com
QR code linking to vmascolino.comvmascolino.com

Backup

Additional material for Q&A

Cross-section variation with fuel depletion

  • Cross sections generated over 1 year of burnup
  • Nu-fission cross sections vary on the order of a few percent
  • Little to no change in other cross sections
Percent change from fresh fuel to 1 year of continuous 250 kW operation (x-y slice; 4 × 4 cm voxels, 124 cm across). Values digitized from the figure’s colors (resolution 0.04 %); dashed line: core.

Changes scale with rod insertion

Derived from the tables on slides 9 and 12; not part of the ANS summary. Mean insertion: the four rods weighted equally (TRAN is air-followed), as a fraction of travel from withdrawn to 900 steps. Lines: fits through zero.

What to see

Core-averaged changes grow almost linearly with how far the rods are in.

References

  1. Reactor vessel being installed at Hinkley Point C, England. nucnet.com, 2026.
  2. Valar Atomics Ward 250 being loaded on a C-17. aerospaceglobalnews.com, 2026.
  3. R. Ponciroli, H. Wang, V. Theos, J. Lau, S. Chatzidakis, and R. B. Vilim, “Ex-Core Neutron-Flux Reconstruction using Machine-Learned Green’s Kernels and Flux-Gradient Measurements,” Nuclear Science and Engineering, 2026. doi:10.1080/00295639.2026.2690565
  4. R. Ponciroli, H. Wang, V. Theos, J. Lau, S. Chatzidakis, and R. B. Vilim, “Who Needs Big Data? Small-Data Flux Reconstruction via Green’s Functions and Ex-Core Detectors,” Proc. PHYSOR 2026.
  5. H. Wang, R. Ponciroli, J. Lau, V. Theos, S. Chatzidakis, and R. B. Vilim, “Measuring Neutron Flux Gradient: Design, Prototyping, and Deployment of a Novel Sensor at the PUR-1 Research Reactor,” Proc. PHYSOR 2026.
  6. JSI TRIGA reactor containment. EURO-LABS, 2026.
→ or clicker: next · ←: back · P: presenter view · R: reveal answer · T: 60 s timer · B: black screen · S: pause animation · F: full screen · G: go to slide